Resources
Products
Residential Building Insulation
Johns Manville’s residential insulation products help maintain energy efficiency and lower heating and cooling costs, making homes more comfortable year round. Johns Manville is committed to providing the high quality products, resources, guidance and on demand support you need on the job.
Attic Protector Blow-In
Johns Manville Attic Protector® Formaldehyde-free™ premium blow-in fiberglass insulation offers effective thermal and acoustical performance. Installed with a portable blowing machine, it's perfect for covering hard-to-reach areas within attics and provides a more efficient installation for homeowners or remodeling professionals.
Advantages
Easy Installation: Insulates attics or spaces of all shapes and sizes without cutting or fitting.
Complete Coverage: Effective in tight spaces, areas with large amounts of cross-bridging or small gaps and voids.
Thermally Efficient: Effective resistance to heat transfer. No settling; no loss of R-value following installation.
Formaldehyde-free: Will not off-gas formaldehyde in the indoor environment.
Sound Control: Reduces sound transmission through exterior and interior walls, floor and ceiling assemblies.
Fire-Resistant: Flame Spread of 25 or less and Smoke Developed of 50 or less.
Resilient Inorganic Glass: No rotting, mildew or deterioration. Also noncorrosive to pipes, wiring and metal studs.
Superior Performance: Stable bonded glass fibers will not slump, settle or break down during normal applications.
ASTM Standards | ASTM C764 | Type I |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 50 |
Critical Radiant Flux | ASTM E970 | > 0.12 W/cm2 (0.11 Btu/ft2s) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM 665 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Combustion Characteristics | ASTM E136 | Pass |
Data Sheet
Attic Protector Blow-In B785 Data Sheet
SDS
Attic Protector Blow-In SDS
Attic Protector Blow-In SDS (ES)
Fact Sheet
Attic Protector Blow-In Fact Sheet
Certifications and Specifications
Cavity-SHIELD Fiberglass
JM Formaldehyde-free™ Cavity-SHIELD™ fiberglass batts are made of long, resilient glass fibers bonded with a thermosetting resin. A wide range of thicknesses are available to provide NFPA 13 compliant passive fire protection in lieu of sprinklers for horizontal floor-ceiling cavities. Cavity-SHIELD fiberglass batts are available unfaced.
Advantages
Noncombustible: ASTM E 136, NFPA 13 Section 9.2.1 compliant
Simple Installation: no special equipment required
Cost-effective: economical alternative to blow-in insulation
Formaldehyde-free: will not off-gas formaldehyde in the indoor environment
Sound Control: reduces transmission of sound through floor or ceiling assemblies
Fire Resistant: Flame Spread of 25 or less and Smoke Developed of 50 or less (ASTM E84), Class A1
Durable Inorganic Glass: will not rot, mildew or deteriorate and is noncorrosive to pipes, wiring and sheet metal ducts
ASTM Standards | ASTM C665 | Type I |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 50 |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM 665 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Combustion Characteristics | ASTM E136 | Pass |
Data Sheet
Literature
Certifications and Specifications
Warranties
Climate Pro Blow-In
Johns Manville Climate Pro® Formaldehyde-free™ blow-in, loose-fill fiberglass insulation offers thermal and sound control along with fire resistance. One bag of Climate Pro provides 77.1 square feet of R-30 coverage. Engineered for professional use with high-volume blowing machines, it's ideal for attics, nonconforming spaces and hard-to-reach areas making the job faster and easier.
Advantages
Easy Installation: Insulates attics or spaces of all shapes and sizes without cutting or fitting.
Complete Coverage: Effective in tight spaces, areas with large amounts of cross-bridging, or small gaps and voids.
Thermally Efficient: Effective resistance to heat transfer. No settling; no loss of R-value following installation.
Formaldehyde-free: Will not off-gas formaldehyde in the indoor environment.
Sound Control: Reduces sound transmission through exterior and interior walls, floor and ceiling assemblies.
Fire-Resistant: Flame Spread of 5 or less and Smoke Developed of 5 or less.
Resilient Inorganic Glass Fibers: No rotting, mildew or deterioration. Also noncorrosive to pipes, wiring and metal studs.
Superior Performance: Stable bonded glass fibers will not slump, settle or break down during normal applications.
ASTM Standards | ASTM C764 | Type I |
Flame Spread | ASTM E84 | ≤ 5 |
Smoke Development | ASTM E84 | ≤ 5 |
Critical Radiant Flux | ASTM E970 | > 0.12 W/cm2 (0.11 Btu/ft2s) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM C764 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Combustible Characteristics | ASTM E136 | Pass |
VOC Emissions | ES Section 01350 | Pass |
Data Sheet
JM Climate Pro B7700 Data Sheet
Installation Instructions
JM Climate Pro B7700 Install Instructions
Climate Pro B-7700 Install Instructions Spanish
Climate Pro PresSure Gauge User Guide
SDS
Climate Pro Blow-In SDS
Climate Pro Blow-In SDS (ES)
Literature
Product Selector Guide
Blowing Wool Coverage Check and Easy Fix Checklist
Blowing Wool Coverage Check and Easy Fix Checklist (ES)
Certification and Specifications
Best Practices for Installing JM Climate Pro®
ComfortTherm
Johns Manville ComfortTherm® poly-encapsulated thermal and acoustical insulation offers R-Values up to R-30 and is available in precut batts to fit standard wall cavities or rolls for custom installation in any size of wall cavity. ComfortTherm® insulation is wrapped in plastic for dust-free, itch-free installation, and can be used in a wide variety of wood frame, engineered wood and steel frame construction applications, including new construction and retrofit.
Note: Color of product may differ based on the manufacturing location.
Advantages
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-30.
Formaldehyde-free: Will not off-gas formaldehyde in the indoor environment.
Sound Control: Reduces sound transmission through exterior and interior walls, floor and ceiling assemblies.
Fire-Resistant: Can be left exposed where building codes permit. Flame Spread of 25 or less and and Smoke Developed of 50 or less.
Resilient Inorganic Glass: No rotting, mildew or deterioration. Also noncorrosive to pipes, wiring and metal studs.
Superior Performance: Stable bonded glass fibers will not slump within the wall cavity, settle or break down during normal applications.
ASTM Standards | ASTM C665 | Type II, Class A, Category 1 or 2 [Standard ComfortTherm is Category 1 (vapor retarder). ComfortTherm for hot, humid climates is Category 2 (non-vapor retarder).] |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 50 |
Water Vapor Permeance |
ASTM E96 | 0.5 Perms (29 ng/Pa-s-m2) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM 665 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Installation Instructions
Fiberglass Installation Instructions
Fiberglass Installation Instructions (ES)
Literature
Warranties
FSK-25 Batts
Johns Manville Formaldehyde-free™ FSK-25 thermal and acoustical fiberglass insulation is available in R-Values up to R-30, and is offered in precut batts to fit standard wall cavities. FSK-25 faced batts combine fire resistance with excellent vapor resistance, and can be used in a wide variety of wood frame, engineered wood and steel frame construction applications, including new construction and retrofit. FSK-25 batts are designed with a foil facer that can be left exposed where codes permit.
Note: Color of product may differ based on the manufacturing location.
Advantages
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-30.
Formaldehyde-free: Will not off-gas formaldehyde in the indoor environment.
Sound Control: Reduces sound transmission through exterior and interior walls, floor and ceiling assemblies.
Fire-Resistant: Flame Spread of 25 or less and Smoke Developed of 50 or less. Can be left exposed where building codes permit.
Resilient Inorganic Glass: No rotting, mildew or deterioration. Also noncorrosive to pipes, wiring and metal studs.
Superior Performance: Stable bonded glass fibers will not slump, settle or break down during normal applications.
ASTM Standards | ASTM C665 | Type III, Class A, Category I |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 50 |
Water Vapor Permeance Facing | ASTM E96 | 0.05 Perms (3 ng/Pa-s-m2) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM 665 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Kraft Faced Fiberglass
Johns Manville Formaldehyde-free™ Kraft-faced thermal and acoustical insulation offers R-Values up to R-49, and is offered in precut batts to fit standard wall cavities or rolls for custom installation in any size cavity. Kraft-faced insulation is ideal for moisture control in exterior walls, reduces sound transmission through walls, ceilings and floors, and can be used in a variety of wood-framed, engineered wood and steel frame construction applications, including new construction and retrofit.
Note: Color of product may differ based on the manufacturing location.
Advantages
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-49.
Formaldehyde-free: Will not off-gas formaldehyde in the indoor environment.
Sound Control: Reduces sound transmission through exterior and interior walls, floor and ceiling assemblies.
Resilient Inorganic Glass: No rotting, mildew or deterioration. Also noncorrosive to pipes, wiring and metal studs.
Superior Performance: Stable bonded glass fibers will not slump within the wall cavity, settle or break down during normal applications.
ASTM Standards | ASTM C665 | Type II, Class C, Category 1 |
Water Vapor Permeance Facing | ASTM E96 | 1.0 Perms (57 ng/Pa-s-m2) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM 665 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Data Sheet
Kraft Faced Fiberglass Data Sheet
SDS
Kraft Faced Fiberglass SDS
Kraft Faced Fiberglass SDS (ES)
Certifications and Specifications
Installation Instructions
Fiberglass Installation Instructions
Fiberglass Installation Instructions (ES)
Literature
Warranties
Panel Deck FSK-25
Johns Manville Panel Deck FSK-25 Formaldehyde-free™ thermal and acoustical insulation is available in R-Values up to R-30 and combines fire resistance with an excellent vapor retarder. Panel Deck FSK-25 insulation is offered in precut batts with extra-wide tabs for modular roof deck applications and other speciality commercial applications. This product is designed with a foil facer that can be left exposed where codes permit.
Note: Color of product may differ based on the manufacturing location.
Advantages
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-30.
Formaldehyde-free: Will not off-gas formaldehyde in the indoor environment.
Sound Control: Reduces sound transmission through exterior and interior walls, floor and ceiling assemblies.
Fire-Resistant: Flame Spread of 25 or less and Smoke Developed of 50 or less. Can be left exposed where building codes permit.
Resilient Inorganic Glass: No rotting, mildew or deterioration. Also noncorrosive to pipes, wiring and metal studs.
Superior Performance: Stable bonded glass fibers will not slump, settle or break down during normal applications.
ASTM Standards | ASTM C665 | Type III, Class A, Category I |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 50 |
Water Vapor Permeance Facing | ASTM E96 | 0.05 Perms (3 ng/Pa-s-m2) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM 665 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Spider Plus Blow-In
Johns Manville Spider® Plus Formaldehyde-free™ blow-in fiberglass insulation uses interlocking fiber technology to fill all gaps and voids quickly with no adhesive or netting for a faster installation. Spider Plus provides complete coverage, with no shrinking or settling, resulting in superior thermal performance and sound control. Designed for use in wood- and metal-frame construction, engineered- wood construction and manufactured homes.
Advantages
Fast Drying: Dries immediately once installed.
Complete Coverage: Effective in tight spaces, areas with large amounts of cross-bridging or small gaps and voids.
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-25 in a 6'' cavity.
Formaldehyde-free: Will not off-gas formaldehyde in the indoor environment.
Sound Control: Reduces sound transmission through exterior and interior walls, floor and ceiling assemblies.
Fire-Resistant: Flame Spread of 25 or less and Smoke Developed of 50 or less.
Resilient Inorganic Glass: No rotting, mildew or deterioration. Also noncorrosive to pipes, wiring and metal studs.
ASTM Standards | ASTM C764 | Type I |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 50 |
Critical Radiant Flux | ASTM E970 | > 0.12 W/cm2 (0.11 Btu/ft2s) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM 665 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Combustion Characteristics | ASTM E136 | Pass |
Data Sheet
Spider Plus Blow-In Data Sheet
SDS
Spider Plus Blow-In SDS
Spider Plus Blow-In SDS (ES)
Sell Sheet
Spider Plus Blow-In Sell Sheet
Certifications and Specifications
Installation Instructions
Spider Plus Consolidated Install Instructions
Spider Plus Consolidated Install Instructions (ES)
Spider Plus Full Install Instructions
Spider Plus Full Install Instructions (ES)
Coverage Card
Spider PLUS Closed Cavities Coverage Card
Literature
Case Study
Unfaced Fiberglass
Johns Manville Formaldehyde-free™ Unfaced thermal and acoustical insulation offers R-Values of up to R-49, and is offered in precut batts to fit standard wall cavities or rolls for custom installation in any size cavity. Unfaced insulation reduces sound transmission through walls, ceilings and floors, and can be used in a variety of wood frame, engineered wood and steel frame construction applications, including new construction and retrofit.
Advantages
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-49.
Formaldehyde-free: Will not off-gas formaldehyde in the indoor environment.
Sound Control: Reduces sound transmission through exterior and interior walls, floor and ceiling assemblies.
Fire-Resistant: Flame Spread of 25 or less and Smoke Developed of 50 or less.
Resilient Inorganic Glass: No rotting, mildew or deterioration. Also noncorrosive to pipes, wiring and metal studs.
Superior Performance: Stable bonded glass fibers will not slump within the wall cavity, settle or break down during normal applications.
ASTM Standards | ASTM C665 | Type I |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 50 |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM 665 | Pass |
Fungi Resistance | ASTM C1388 | Pass |
Combustion Characteristics | ASTM E136 | Pass |
Installation Instructions
Fiberglass Installation Instructions
Fiberglass Installation Instructions (ES)
Literature
STC Rating Documents
Acoustical Assemblies STC Rating Reference Guide
Certifications and Specifications
JM CladStone Water & Fire Block Mineral Wool
Johns Manville CladStone™ Water & Fire Block insulation is manufactured from inorganic fibers derived from volcanic rock. Advanced manufacturing technology ensures consistent product quality, with high-fiber density and low shot content for excellent performance. Noncombustible, with water-repellent properties, it is ideal for exterior cavity wall and rainscreen applications. Available in 4 densities, CladStone 45 (4.5pcf), CladStone 60 (6.0 pcf), CladStone 80 (8.0 pcf) and CladStone 110 (11.0 pcf).
Advantages
Water-Repellent: Repels water to ensure drainage when applied as part of a proper exterior wall cavity system.
Fire-Resistant: Melting point in excess of 2000˚F (1093˚C). Flame Spread of 0 and
Smoke Developed of 0.
Durable Inorganic Glass: No growth of fungi. No sustaining of vermin.
Densities: CladStone 45 (4.5pcf), CladStone 60 (6.0 pcf), CladStone 80 (8.0 pcf) and CladStone 110 (11.0 pcf)
ASTM Standards | ASTM C665 | Type I |
Thermal Resistance | ASTM C518 | R-4.3 per inch |
Flame Spread | ASTM E84 | 0 |
Smoke Development | ASTM E84 | 0 |
Water Vapor Permeance Facing | ASTM E96 | Unfaced, 50 perms as tested |
Water Vapor Sorption | ASTM C1104 | Absorbs 0.03% by volume |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM C665 | Pass |
Fungi Resistance | ASTM C1338 | Pass |
Combustion Characteristics | ASTM E136 | Pass |
ASTM C612 | Type IA, IB, II, III, IVA, IVB | |
ASTM C356 | Linear shrinkage < 2% 1200° F (650° C) | |
ASTM C1335 | Shot content less than 25% |
Data Sheet
JM CladStone 45 Water & Fire Block Data Sheet
JM CladStone 60 Water & Fire Block Data Sheet
JM CladStone 80 Water & Fire Block Data Sheet
JM CladStone 110 Water & Fire Block Data Sheet
JM CladStone Retaining Clips Data Sheet
SDS
JM CladStone Water & Fire Block SDS
JM CladStone Water & Fire Block SDS (ES)
Installation Instructions
JM CladStone Water & Fire Block Installation Instructions
Specifications and Certificates
CladStone Water and Fire Block
Industrial Insulation Group (IIG) Relationship
Mineral Wool Environmental Product Declaration (Light Density)
Mineral Wool Environmental Product Declaration (Heavy Density)
Limited Warranty
Literature
Product Selector Guide
Mineral Wool Product Comparison Chart
Mineral Wool 2.0 Sell Sheet
CladStone Sell Sheet
Building Envelope Solutions
Wall Assemblies
Continuous Insulation for Rain-Screen Cladding Systems - Metal Panel
Continuous Insulation for Rain-Screen Cladding Systems - Fiber Cement Panel
Continuous Insulation for Cavity Wall Systems
Sound & Fire Block Mineral Wool
Johns Manville Sound & Fire Block® mineral wool batts are noncombustible and moisture-resistant. The high-density fibers in mineral wool help delay the spread of fire and reduce noise transfer in interior walls and between ceilings and floors.
Advantages
Sound Control: Absorbs sound and improves wall assembly STC ratings by up to 10 dB.
Fire-Resistant: Melting point in excess of 2000˚F (1093˚C). Flame Spread of 0 and Smoke Developed of 0.
Durable Inorganic Glass: No growth of fungi. No sustaining of vermin.
ASTM Standards | ASTM C665 | Type I |
Flame Spread | ASTM E84 | 0 |
Smoke Development | ASTM E84 | 0 |
Critical Radiant Flux | ASTM E970 | > 0.12 W/cm2 (0.11 Btu/ft2s) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM C665 | Pass |
Fungi Resistance | ASTM C1338 | Pass |
Combustion Characteristics | ASTM E136 | Pass |
Limited Warranty
Literature
Product Selector Guide
Mineral Wool Product Comparison Chart
Mineral Wool 2.0 Sell Sheet
MinWool Typical Sound Barrier Assemblies
Specifications and Certificates
Mineral Wool Environmental Product Declaration (Light Density)
Mineral Wool Environmental Product Declaration (Heavy Density)
TempControl Mineral Wool
Johns Manville Mineral Wool TempControl® batts offer R-Values up to R-30. Noncombustible, fire- and moisture-resistant, they are designed to deliver thermal control and delay the spread of fire in wood-stud cavities of exterior walls, basements and heated crawlspaces.
Advantages
Thermally Efficient: Effective resistance to heat transfer with R-values up to R-30.
Fire-Resistant: Melting point in excess of 2000˚F (1093˚C). Flame Spread of 0 and Smoke Developed of 0.
Durable Inorganic Glass: No growth of fungi. No sustaining of vermin.
ASTM Standards | ASTM C665 | Type 1 |
Thermal Resistance | ASTM C518 | R-15, R-23, R-30 |
Flame Spread | ASTM E84 | 0 |
Smoke Development | ASTM E84 | 0 |
Critial Radiant Flux | ASTM E970 | > 0.12 W/cm2 (0.11 Btu/ft2s) |
Water Vapor Sorption | ASTM C1104 | 5% or less by weight |
Odor Emission | ASTM C1304 | Pass |
Corrosiveness | ASTM C665 | Pass |
Fungi Resistance | ASTM C1338 | Pass |
Combustion Characteristics | ASTM E136 | Pass |
Limited Warranty
Literature
Product Selector Guide
Mineral Wool Product Comparison Chart
Mineral Wool 2.0 Sell Sheet
Specifications and Certificates
Mineral Wool Environmental Product Declaration (Light Density)
Mineral Wool Environmental Product Declaration (Heavy Density)
JM Corbond High Yield Open-Cell
JM Corbond® High Yield Open-cell (HY OC) Spray Polyurethane Foam insulation is a two-component, low-density, E84 Class A rated, nonstructural insulation system designed for interior commercial, residential and industrial applications. JM Corbond HY OC is 100% water blown. JM Corbond HY OC offers the highest yield of any JM Corbond open-cell product. Its superior performance and exceptional sprayability make it an ideal choice for high-performing energy efficient buildings.
SPF Acceptance Criteria | ASTM AC377 | Pass |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 450 |
Fungi Resistance | ASTM E283 | Pass |
Dimensional Stability | ASTM D2126 | -8.8% Change in Volume |
Core Density | ASTM D1622 | 0.4 pcf (normal) |
Air Permeance | ASTM E2178-03 | < 0.02 (L/s)/m |
DATA SHEET
JM Corbond HY OC Data Sheet
JM Corbond HY OC Data Sheet (ES)
SDS
JM Corbond SDS - A
JM Corbond SDS - A (ES)
JM Corbond HY OC SDS - B
JM Corbond HY OC SDS - B (ES)
LITERATURE
Product Selector Guide
TechConnect Sell Sheet
JM Corbond High Yield Open-Cell FAQ
INSTALLATION INSTRUCTIONS
JM Corbond High Yield Open-Cell Installation Guide
JM Corbond High Yield Open-Cell Installation Guide (ES)
SPF Processing Parameters
SPF Change-over Procedure
SPF Change-over Procedure (ES)
SPF Safety Warning Sign
SPF Health and Safety Sheet
Corbond Daily Work Log
EVALUATION REPORTS
JM Corbond OC Code Compliance Research Report (CCRR-1079)
EPD for Spray Polyurethane Foam Insulation Open Cell (OCSPF)
JM Corbond III
Johns Manville Corbond® III closed-cell spray polyurethane foam insulation offers and R-Value of R-7 per inch and can be applied in a single pass to a maximum of 3.5 inches, providing superior thermal performance with seamless air sealing and moisture control in a single step. Multiple immediate passes, with no wait time, may also be applied. With high yield and excellent adhesion, it's an ideal choice for high-performing energy efficient commercial, residential and industrial applications.
Advantages
Complete Coverage: Expands and adheres without shrinking or settling.
Energy-Efficient: Reduces air and moisture infiltration to the building envelope and provides continuous coverage for high thermal performance.
Air Barrier: Prevents leaks when installed at 1” thickness or more.
Moisture Performance: Resists mold growth; meets current vapor retarder codes.
Wide Application Temperature Range: Can be applied between 20°F and 120°F , delivering consistent performance with seasonal versatility.
Faster Installation: Spray easily in a single pass from a minimum of .5" to a maximum of 3.5”. Multiple immediate passes, with no wait time, may also be applied. See Data Sheet for complete information.
Commercial Approvals: NFPA 285 assembly approvals. Appendix X approval for application in unoccupied attics and crawl spaces without a prescriptive ignition barrier or coating.
SPF Acceptance Criteria | ASTM AC377 | Pass |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 450 |
Fungi Resistance | ASTM C1388 | Pass |
Dimensional Stability | ASTM D2126 | < 15% change in volume |
Nominal Density | ASTM D1622 | 2 pcf |
Closed-Cell Content | ASTM D6226 | > 90% |
Compressive Strength (1”) | ASTM D1621 | 36 psi |
Water Absorption | ASTM D2842 | 0.9% |
Water Vapor Transmission | ASTM E96 | 0.61 perms @ 1.5" |
Air Permeance | ASTM E2178-03 | 0.00055 (L/s)/m at 75 Pa |
Sound Transmission | ASTM E90-90, ASTM E413-87 | 36 (STC) |
Data Sheet
SDS
JM Corbond SDS - A
JM Corbond SDS - A (ES)
JM Corbond Closed-cell SDS - B
JM Corbond Closed-cell SDS - B (ES)
Literature
Product Selector Guide
Exploring the Efficacy of High Lift Spray Foam Insulation White Paper
JM Spray Foam Overview Brochure
TechConnect Sell Sheet
JM Spray Foam Trial and Technical Support Brochure
JM Corbond III Seasonal FAQ
JM Spray Foam Parts and Equipment (Fusion AP)
STC Rating Documents
Acoustical Assemblies STC Rating Reference Guide
Installation Instructions
JM Corbond III SPF Installation Guide
SPF Processing Parameters
SPF Change-over Procedure
SPF Change-over Procedure (ES)
SPF Safety Warning Sign
SPF Health and Safety Sheet
Corbond Daily Work Log
Certificates
JM Corbond Re-Occupancy Certificate
JM Corbond Insulation Certificate
Spray Foam Certification
Technical Bulletins
JM Corbond III Air Barrier Advantage
Hybrid ccSPF + Fiberglass Wall Recommendations
Application Guides
Penetrations - Ambient Temperature
Below Grade Wall
Change in Substrate
Crawl Space
Expansion Joint
Floor Slab to Foundation Wall
Framed Floor to Foundation Wall
High Temperature Penetrations
Interstory Connections
Parapet
Substrate Joints and Defects
Unvented Attic Insulated Roof Deck
Unvented Attic Insulated Roof Deck V2
Vaulted Ceiling
Vented Attic
Wall Corner
Window Head
Evaluation Reports
Corbond III IAPMO Evaluation Report
Environmental Product Declaration Spray Polyurethane Foam Insulation (HFC) Report
Life Cycle Assessment of Spray Polyurethane Foam Insulation Report
Specifications
JM Corbond III Greenguard
JM Corbond III Greenguard Gold
JM Corbond III
Case Studies
All-American House Case Study
Jay Peak Resort Case Study
Vision House Case Study
Project Profile
JM Corbond IV
JM Corbond® IV closed-cell spray polyurethane foam (SPF) is a next generation HFO blown, two-component, Class 1 rated, medium-density, SPF insulation system. JM Corbond IV is designed to insulate commercial, residential, and industrial buildings. The HFO technology allows JM Corbond IV to be produced with a low Global Warming Potential (GWP) and with an Ozone Depletion Potential (ODP) of zero. Its high yield, superior thermal and moisture performance, and exceptional sprayability and adhesion make it an ideal choice for high-performing energy efficient buildings.
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 450 |
Fungi Resistance | ASTM C1388 | Pass |
Dimensional Stability | ASTM D2126 | 12% change in volume |
Core Density | ASTM D1622 | 2.0 lb/ft3 |
Closed-Cell Content | ASTM D6226 | > 90% |
Compressive Strength (1") | ASTM D1621 | 36 psi |
Water Absorption | ASTM D2842 | 0.88% |
Water Vapor Transmission | ASTM E96 | 0.61 perm at 1.5", 1.1 perm at 1" |
Air Permeance | ASTM E2178-03 | 0.00055 (L/s)/m at 75 Pa |
Sound Transmission | ASTM E90-90, ASTM E413-87 | 36 (STC) |
DATA SHEET
SDS
JM Corbond SDS - A
JM Corbond SDS - A (ES)
JM Corbond IV Closed-cell SDS - B
JM Corbond IV Closed-cell SDS - B (ES)
LITERATURE
Product Selector Guide
JM Corbond IV Guide
TechConnect Sell Sheet
Building Envelope Solutions
INSTALLATION INSTRUCTIONS
JM Corbond IV Installation Guide
SPF Processing Parameters
SPF Change-over Procedure
SPF Change-over Procedure (ES)
SPF Safety Warning Sign
SPF Health and Safety Sheet
Corbond Daily Work Log
EVALUATION REPORTS
Environmental Product Declaration Spray Polyurethane Foam Insulation (HFO) Report
JM Corbond IV IAPMO Report (ER 0146)
EPD for Spray Polyurethane Foam Insulation Closed Cell Using Hydrofluoroolefins (CCSPF, HFO)
CERTIFICATES
Project Profile
JM Corbond Open-cell
Johns Manville Corbond® Open-cell Spray Foam is a lower density, nonstructural insulation that offers an R-Value of R-3.8 per inch. It delivers high yield, minimizes sound transmission and virtually eliminates any air leakage. It's designed to improve energy efficiency for a wide variety of residential, commercial and industrial applications and can act as an effective air barrier.
Advantages:
Energy-Efficient: Helps to improve energy efficiency by filling in gaps and cracks while creating an air seal.
Air Barrier: Air-impermeable at 3.75”.
Sound Transmission: Performs well acoustically when used in an assembly.
Installation: Provides high yield with superior sprayability at an exceptional value and low odor. Meets requirements for application without an ignition barrier attics and crawl spaces.
SPF Acceptance Criteria | ASTM AC377 | Pass |
Flame Spread | ASTM E84 | ≤ 25 |
Smoke Development | ASTM E84 | ≤ 450 |
Fungi Resistance | ASTM E283 | Pass |
Dimensional Stability | ASTM D2126 | < 15% change in volume |
Nominal Density | ASTM D1622 | 0.5 pcf (normal) |
Open-Cell Content | ASTM D6226 | > 92% |
Water Vapor Transmission | ASTM E96 | 26.5 perms @ 2" |
Air Permeance | ASTM E2178-03 | < 0.02 (L/s)/m |
Sound Transmission | ASTM E90-90, ASTM E413-87 | 38 (STC) |
Data Sheet
JM Corbond oc SPF Data Sheet (US)
SDS
JM Corbond SDS - A
JM Corbond SDS - A (ES)
JM Corbond ocSPF SDS - B
JM Corbond ocSPF SDS - B (ES)
Literature
Product Selector Guide
JM Spray Foam Overview Brochure
JM Spray Foam Trial and Technical Support Brochure
TechConnect Sell Sheet
JM Corbond oc ocx Sell Sheet
JM Spray Foam Parts and Equipment (Fusion AP)
Spray Foam Certification
Specifications
Installation Instructions
JM Corbond oc SPF Processing Parameters
JM Corbond oc SPF Processing Parameters (ES)
JM Corbond® SPF Change Over Procedure
JM Corbond SPF Change-over Procedure (ES)
JM Corbond oc SPF Installation Guide
SPF Safety Warning Sign
SPF Health and Safety Sheet
JM Corbond Re-Occupancy Certificate
JM oc SPF for Unvented Attics Insulation Certificate
Unvented Attic Hatch Guide
Corbond Daily Work Log
Evaluation Reports
Code Compliance Research Report CCRR-1079
Environmental Product Declaration Spray Polyurethane Foam Insulation (HFC) Report
Life Cycle Assessment of Spray Polyurethane Foam Insulation Report
EPD for Spray Polyurethane Foam Insulation Open Cell (OCSPF)
Certificates
JM Corbond OC SPF VOC Emission Test Certificate
JM Corbond Insulation Certificate
Case Study
Project Profile
No-Burn Plus ThB
Johns Manville has partnered with No-Burn, Inc. to offer No-Burn Plus ThB. This tintable white, thin film intumescent coating can be applied over JM open- and closed-cell polyurethane foams. When exposed to high temperatures and flame it intumesces, which creates a char-barrier to reduce heat transfer and surface burning in the event of a fire. This nontoxic, water-based coating complies with IRC and IBC and can serve in lieu of otherwise code-prescribed thermal barriers.
Color | Opaque/White/Tinted |
Finish | Flat |
VOC Content | 18 g/L EPA Method 24 |
Dry Time | 60-90 minutes |
Pails | 5 gallons (19 L), 57.5 lbs. |
Drums | 55 gallons (208 L), 632.5 lbs. |
Shelf Life | 18 months |
Cure Time | 24 hours |
Boiling Point | 212°F |
Freezing Point | 32°F |
% Volatile by Volume | 33% |
Specific Gravity | 1.25 |
Data Sheet
JM No-Burn Plus ThB Data Sheet
SDS
JM No-Burn Plus ThB White SDS
JM No-Burn Plus ThB SDS (ES)
JM No-Burn Black Tint SDS
JM No-Burn Black Tint SDS (ES)
No-Burn Plus ThB Custom Color Tint
No-Burn Plus ThB Custom Color Tint (ES)
No-Burn Plus ThB Gray
No-Burn Plus ThB Gray (ES)
No-Burn Plus ThB Dark Charcoal
No-Burn Plus ThB Dark Charcoal (ES)
Literature
Evaluation Report
ER-305
TER 1905-03
JM Corbond III and Corbond IV IAPMO Report (ER 0146)
Certificates
Bulletins
Spray Foam Parts and Equipment
We have on-staff experts designated to helping you select the right parts and equipment for your spray foam rig. Our spray foam team has access to an extensive catalog of spray foam parts and equipment with overnight shipping capabilities for emergencies. You can connect with our technical service representative via phone, email, video calls or even text message to ensure you are ordering the correct part. Click here for more details.
Vent Chutes
Johns Manville Vent Chutes are extruded polystyrene (XPS) sheets thermoformed to provide airflow from the soffit to the attic space when installed between insulation and the roof deck. Johns Manville Vent Chutes can be installed in finished or unfinished attics with open rafters in both new and retrofit construction to fit both 16" and 24" on-center cavities.
Advantages:
- Adjustable: can easily be modified to fit both 16" and 24" on center cavities.
- Venting: help optimize performance of attic insulation by minimizing wind washing, prevent blown insulation from blocking the air-flow, keep the space between soffit vents and attic space open during construction and maintain air channels over time.
JM Vent Chutes are packaged in bags of 50 vents.
Width | Pieces Per Bag | Bags Per Unit | Net Free Airlow |
48"x 22.5" | 50 | 32 | 22.8 sq. in. |
Data Sheet
AP Foil-Faced Foam Continuous Insulation
Johns Manville AP™ Foil-Faced Polyiso Foam Sheathing boards are available in R-Values up to R-28 and offer a reflective foil facer on one side and a non-reflective facer on the other. AP Foil provides exceptional heat, moisture and air control and, when installed correctly, eliminates all major thermal bridges that cause heat loss. The rigid continuous insulation board allows for maximum wall and worksite efficiency.
Advantages
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-28.
Water-Resistive Barrier: Meets the ICC-ES AC71 acceptance criteria.
Vapor Barrier: Class I vapor retarder at one inch.
Air Barrier: Meets the Air Barrier Association of America boardstock criteria, when properly installed.
Lightweight: Easy to handle and may be cut with a utility knife or saw.
ASTM Standards | ASTM C1289 | Type I, Class 1 |
Flame Spread | ASTM E84 | 4": ≤ 25 |
Smoke Development | ASTM E84 | ≤ 450 |
Water Vapor Transmission | ASTM E96 | 0.05 perms (3 ng/Pa-s-m2) |
Compressive Strength | ASTM D1621 | ≥ 16 psi (110 kPa) |
Water Absorption | ASTM C209 | 0.1% volume |
Service Temperature | -100 to 250°F | |
R-Value Per Inch | 6.0 |
Data Sheet
AP Foil-Faced Foam Sheathing Data Sheet
SDS
AP Foil-Faced Foam Sheathing SDS
AP Foil-Faced Foam Sheathing SDS (ES)
Installation Instructions
JM Continuous Insulation Wall System Installation Guide
Technical Bulletin 302: Wall Bracing with Polyiso CI
JM AP Foil Faced Sheathing Below-Grade Interior Walls Installation Instructions
JM AP Foil Faced Sheathing Below-Grade Exterior Walls Installation Instructions
JM AP Foil Faced Sheathing Crawl Spaces Installation Instructions
AP Foil Faced Insulation Sheathing Board Attics and Cathedral/Vaulted Ceiling Installation Instructions
AP Foil Residential Installation Instructions - Above Grade Exterior Walls,Technical Guide
Technical Bulletin
JM AP Foil - NFPA 285 Wall Assemblies
STC Rating Documents
Acoustical Assemblies STC Rating Reference Guide
Wall Assemblies
Continuous Insulation for Stucco Wall Systems - Option One
Continuous Insulation for Stucco Wall Systems - Option Two
Continuous Insulation for Stucco Wall Systems - Option Three
Continuous Insulation Wall System
Continuous Insulation
Continuous Insulation Website
Technical Bulletin 301: Polyiso CI Performance in Residential Wall Applications
Technical Bulletin 303: Moisture Control with Polyiso CI
Technical Bulletin 304: Energy Efficiency with Polyiso CI
Evaluation Reports
Literature
Product Selector Guide
JM All-Purpose Wall System Sell Sheet
PIMA - Polyiso Wall Insulation Boards EPD
PIMA Performance Bulletin - Polyiso vs. XPS
JM All-Purpose Wall System Components Sheet
NFPA 285 ACM Assemblies Announcement
Building Envelope Solutions
Certifications and Specifications
JM Continuous Insulation Wall System Specification, Section 072100 - Foil Faced Rigid Insulation
Polyiso Sheathing EPD
Intertek Clean Air Certification Report
Case Study
JM Castle Pines Case Study
Vision House Case Study
Warranties
AP Foil25 Polyiso Continuous Insulation
Johns Manville AP™ Foil25 Polyiso Continuous Insulation is a 25-psi compressive strength board that consists of a closed-cell polyisocyanurate foam core bonded on each side to a foil facer. AP Foil25 is well suited for below-grade residential applications, as well as commercial applications where higher compressive strength boards are preferred for certain exterior cladding systems. AP Foil25 is a water-resistive barrier, vapor barrier and air barrier all in one.
Advantages
- Thermally efficient: Inch for inch, polyiso has one of the highest energy efficiencies
- Water-resistive barrier: Meets ICC-ES AC71 acceptance criteria
- Vapor barrier: Class I vapor retarder
- Air barrier: Meets the Air Barrier Association of America boardstock criteria when properly installed
- Noncorrosive: Does not accelerate corrosion of pipes, wiring or metal studs
ASTM Standards | ASTM C1289 | Type I, Class 1 |
Flame Spread | ASTM E84 | 4": ≤ 25 |
Smoke Development | ASTM E84 | ≤ 450 |
Water Vapor Transmission | ASTM E96 | 0.05 perms (3 ng/Pa-s-m2) |
Compressive Strength | ASTM D1621 | ≥ 25 psi |
Water Absorption | ASTM C209 | 0.1% volume |
Service Temperature | -100 to 250°F | |
R-Value Per Inch | 6.0 |
Data Sheet
SDS
AP Foil-Faced Foam Sheathing SDS
AP Foil-Faced Foam Sheathing SDS (ES)
Installation Instructions
JM Continuous Insulation Wall System Installation Guide
Technical Bulletin 302: Wall Bracing with Polyiso CI
JM AP Foil Faced Sheathing Below-Grade Interior Walls Installation Instructions
JM AP Foil Faced Sheathing Below-Grade Exterior Walls Installation Instructions
JM AP Foil Faced Sheathing Crawl Spaces Installation Instructions
AP Foil Faced Insulation Sheathing Board Attics and Cathedral/Vaulted Ceiling Installation Instructions
AP Foil Residential Installation Instructions - Above Grade Exterior Walls,Technical Guide
Continuous Insulation
Continuous Insulation Website
Technical Bulletin 301: Polyiso CI Performance in Residential Wall Applications
Technical Bulletin 303: Moisture Control with Polyiso CI
Technical Bulletin 304: Energy Efficiency with Polyiso CI
Evaluation Reports
Literature
Product Selector Guide
JM All-Purpose Wall System Sell Sheet
PIMA - Polyiso Wall Insulation Boards EPD
PIMA Performance Bulletin - Polyiso vs. XPS
JM All-Purpose Wall System Components Sheet
NFPA 285 ACM Assemblies Announcement
Building Envelope Solutions
Certifications and Specifications
JM Continuous Insulation Wall System Specification, Section 072100 - Foil Faced Rigid Insulation
Polyiso Sheathing EPD
Intertek Clean Air Certification Report
Warranties
CI Max Foam Continuous Insulation
Johns Manville CI Max® Polyiso Foam Continuous Insulation is available in R-Values up to R-26 and provides a layer of insulation to reduce thermal bridging and improve energy efficiency. CI Max Continuous Insulation is designed for exposed interior applications and is approved for use without a thermal barrier. It is suitable for wall or ceiling applications in residential, commercial, agricultural and industrial buildings.
Advantages
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-26.
Vapor Barrier: Maintains a minimum thickness of one inch and qualifies as a Class I vapor retarder.
Lightweight: Easy to handle and may be cut with a utility knife or saw.
ASTM Standards | ASTM C1289 | Type I, Class 1 |
Flame Spread | ASTM E84 | 4": ≤ 25 |
Smoke Development | ASTM E84 | ≤ 450 |
Water Vapor Transmission | ASTM E96 | 0.02 perms (1.4 ng/Pa-s-m2) |
Compressive Strength | ASTM D1621 | ≥ 16 psi (110 kPa) |
Water Absorption | ASTM C209 | < 0.6% volume |
Service Temperature | -100 to 250°F | |
R-Value Per Inch | 6.0 |
Data Sheet
CI Max Foam Sheathing Data Sheet
SDS
CI Max Foam Sheathing SDS
CI Max Foam Sheathing SDS (ES)
Installation Instructions
CI Max for Exposed Interior Use
Warranties
Literature
Product Selector Guide
PIMA - Polyiso Wall Insulation Boards EPD
PIMA Performance Bulletin - Polyiso vs. XPS
JM All-Purpose Wall System Components Sheet
Evaluation Reports
Certifications and Specifications
JM CI Max Guide Specifications in CSI Format
JM Continuous Insulation Wall System Specification, Section 072100 - Foil Faced Rigid Insulation
Polyiso Sheathing EPD
Intertek Clean Air Certification Report
R-Panel Roof Insulation
Johns Manville R-Panel® rigid roof insulation board offers R-Values of up to R-23.6, providing high thermal efficiency. R-Panel is manufactured with a closed-cell polyisocyanurate foam core bonded to fiberglass-reinforced facers and designed for use over metal, nailable and non-nailable roof decks with a variety of membrane systems. R-Panel meets the International Building Code requirements for a foamed plastic roof insulation.
Advantages
Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-23.6.
Universal Facer: Compatible with BUR, modified bitumen and single-ply membrane systems.
Clean Air: Meets Clean Air Act Amendments of 1990.
Miami-Dade County Product Control Approved: Complies with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
Lightweight: Easy to handle and may be cut with a utility knife or saw.
ASTM Standards | ASTM C1289-01 | Type II, Class I, Grade 2 |
Flame Spread | ASTM E84 | ≤ 75 |
Smoke Development | ASTM E84 | ≤ 450 |
Water Vapor Transmission | ASTM E96 | < 1 perms (57.5 ng/Pa-s-m2) |
Compressive Strength | ASTM D1621 | ≥ 20 psi (138 kPa)† |
Dimensional Stability | ASTM D2126 | 2% max, 7 days (length & width) |
Water Absorption | ASTM C209 | < 1% volume |
Service Temperature | -100 to 250°F | |
R-Value Per Inch | 5.7 LTTR |