Fasteners and Plates
- Family Description
- JM provides a wide range of fasteners suited for nearly any application. Our expansive line of fasteners and plates also offers induction-weld solutions for TPO and PVC systems.
When it comes to design, we've got the tools to get you from the desk to the roof. Here you will find all of the fastening patterns for fasteners and plates. If you have any questions when it comes to installation, please contact our Specifier Services Group for design and your local technical representative for the field.
2x4 Ft. Roof Insulation Fastener Placement
4x4 Ft. Roof Insulation Fastener Placement
4x8 Ft. Roof Insulation Fastener Placement
BM-12,12,12 Mechanically Fastened Base Sheet (12", 12", 12" o.c.)
BM-7,7,7 Mechanically Fastened Base Sheet (7", 7", 7" o.c.)
BM-7,9,9 Mechanically Fastened Base Sheet (7", 9", 9" o.c.)
BM-75,75,75 Mechanically Fastened Base Sheet (7.5", 7.5", 7.5" o.c.)
BM-9,12,12 Mechanically Fastened Base Sheet (9", 12", 12" o.c.)
BM-9,18,18 Mechanically Fastened Base Sheet (9", 18", 18" o.c.)
BM-9,9,9 Mechanically Fastened Base Sheet (9", 9", 9" o.c.)
FA-16 Fully Adhered Cover (16-24-32)
FA-8 Fully Adhered Cover (8-16-32)
CBUA-12-6-4 Cover Board Urethane Adhesive Fastening
ICBUA-8-4-4 Insulation and Cover Board Urethane Adhesive Fastening
ICBUA-12-6-4 Insulation and Cover Board Urethane Adhesive Fastening
2x4 Ft. Roof Insulation Fastener Placement
4x4 Ft. Roof Insulation Fastener Placement
4x8 Ft. Roof Insulation Fastener Placement
BM-12 Mechanically Fastened Base Sheet (12" o.c.)
BM-12,12,12 Mechanically Fastened Base Sheet (12", 12", 12" o.c.)
BM-18 Mechanically Fastened Base Sheet (18" o.c.)
BM-6 Mechanically Fastened Base Sheet (6" o.c.)
BM-7,7,7 Mechanically Fastened Base Sheet (7", 7", 7" o.c.)
BM-7,9,9 Mechanically Fastened Base Sheet (7", 9", 9" o.c.)
BM-75,75,75 Mechanically Fastened Base Sheet (7.5", 7.5", 7.5" o.c.)
BM-9,12,12 Mechanically Fastened Base Sheet (9", 12", 12" o.c.)
BM-9,18,18 Mechanically Fastened Base Sheet (9", 18", 18" o.c.)
BM-9,9,9 Mechanically Fastened Base Sheet (9", 9", 9" o.c.)
FA-16 Fully Adhered Cover (16-24-32)
FA-8 Fully Adhered Cover (8-16-32)
CBUA-12-6-4 Cover Board Urethane Adhesive Fastening
ICBUA-8-4-4 Insulation and Cover Board Urethane Adhesive Fastening
ICBUA-12-6-4 Insulation and Cover Board Urethane Adhesive Fastening
INUA-12-6-4 Insulation Urethane Adhesive Fastening
BM-9,9,9-TS Tape and Staple Attached Base Sheet (9", 9", 9" o.c.)
BM-9,9,9,9-TS Tape and Staple Attached Base Sheet (9", 9", 9", 9" o.c.)
2x4 Ft. Roof Insulation Fastener Placement - Adhered, Ballasted
4x4 Ft. Roof Insulation Fastener Placement - Adhered, Ballasted
4x8 Ft. Roof Insulation Fastener Placement - Adhered, Ballasted
EM-6 Mechanically Attached JM Reinforced EPDM (6" O.C.)
EM-12 Mechanically Attached JM Reinforced EPDM (12" O.C.)
EMR-6 10" RPS and Mechanically Fastened JM EPDM (6" O.C.)
EMR-12 10" RPS and Mechanically Fastened JM EPDM (12" O.C.)
FA-16 Fully Adhered Cover (16-24-32)
FA-8 Fully Adhered Cover (8-16-32)
CBUA-12-6-4 Cover Board Urethane Adhesive
ICBUA-8-4-4 Insulation and Cover Board Urethane Adhesive
2x4 Ft. Roof Insulation Fastener Placement - Mechanically Fastened, Adhered
4x4 Ft. Roof Insulation Fastener Placement - Mechanically Fastened, Adhered
4x8 Ft. Roof Insulation Fastener Placement - Mechanically Fastened, Adhered
JM PVC RhinoPlate Fastening System 6-10-15
JM PVC RhinoPlate Fastening System 8-15-20
PM-12 FULL JM PVC Mechanically Fastened (12" O.C.)
PM-12 Mechanically Fastened JM PVC (12" O.C.)
PM-18 Mechanically Fastened JM PVC (18" O.C.)
PM-6 FULL JM PVC Mechanically Fastened (6" O.C.)
PM-6 Mechanically Fastened JM PVC (6" O.C.)
FA-16 Fully Adhered Cover (16-24-32)
FA-8 Fully Adhered Cover (8-16-32)
PUA-4-4-4 PVC-FB Urethane Adhesive
PUA-6-4-4 PVC-FB Urethane Adhesive
PUA-12-6-4 PVC-FB Urethane Adhesive
CBUA-12-6-4 Cover Board Urethane Adhesive
ICBUA-8-4-4 Insulation and Cover Board Urethane Adhesive
2 PLY SBS Bonded to Insulation Assembly Plate
2 PLY SBS Mechanically Fastened Base Sheet Over Insulation Assembly Plate
3 PLY SBS Bonded to Insulation Assembly Plate
3 PLY SBS Including Nailed Base Sheet Assembly Plate
3 PLY SBS Mechanically Fastened Base Sheet Ovetr Insulation Assembly Plate
2x4 Ft. Roof Insulation Fastener Placement - Mechanically Fastened, Adhered
4x4 Ft. Roof Insulation Fastener Placement - Mechanically Fastened, Adhered
4x8 Ft. Roof Insulation Fastener Placement - Mechanically Fastened, Adhered
JM TPO RhinoPlate Fastening System 6-10-15
JM TPO RhinoPlate Fastening System 8-15-20
T-RSPR-1 RhinoPlate® Fastened TPO Membrane to Purlins
T-RSPR-2 RhinoPlate® Fastened TPO Membrane - Edge Flashings – Gravel Stop
T-RSPR-3 RhinoPlate® Fastened TPO Membrane - Edge Flashings – Gutter
TM-12 Full Mechanically Fastened JM TPO (12" O.C.)
TM-12 Mechanically Fastened JM TPO (12" O.C.)
TM-18 Mechanically Fastened JM TPO (18" O.C.)
TM-6 Full Mechanically Fastened JM TPO (6" O.C.)
TM-6 Mechanically Fastened JM TPO (6" O.C.)
TMR-12 10" RPS and Mechanically Fastened JM TPO (12" O.C.)
TMR-6 10" RPS and Mechanically Fastened JM TPO (6" O.C.)
TUA-4-4-4 TPO-FB Urethane Adhesive
TUA-6-4-4 TPO-FB Urethane Adhesive
TUA-12-6-4 TPO-FB Urethane Adhesive
CBUA-12-6-4 Cover Board Urethane Adhesive
ICBUA-8-4-4 Insulation and Cover Board Urethane Adhesive
When it comes to your roof, hail can cause significant damage. However, incorporating the appropriate cover board into your roofing system can provide you with superior protection. Upgrade your roof to VSH-rated with DexCell FA VSH Glass Mat Roof Board today!
Very Severe Hail is two inches or wider in diameter.
Hail can fall as speeds up to 72 mph
The Very Severe Hail region was recently expanded. Are you in the danger zone? Visit the FM Global natural hazards map here.
Our JM approved contractors can take advantage of hands-on training and learn all the latest best practices for your profession through our learning program. As low-slope roof technology, materials and performance demands evolve, it is crucial to understand new materials and technologies. JM has built an education and development initiative that utilizes our over 160 years of experience in commercial roofing.
Our BURSI® program, run by our Specifier Services Team offers customizable education programs that are certified by American Institute of Architects (AIA). We offer anything from one-hour “Lunch and Learns” to a 10-hour, multiple-day seminar. Our program is known as (BURSI) Better Understanding of Roofing Systems Institute. Please contact your local sales representative for more information on upcoming BURSI dates or visit our calendar to see the next educational seminar is in your area.