Polyester-Reinforced, APP Mineral-Surfaced Cap or Flashing Sheet
Product Short Description
APPeX® 4.5M is a cap or flashing sheet with ceramic-coated roofing granules that are specifically engineered for optimal embedment in the APP-blended sheet. The membrane is made up of an APP (Atactic Polypropylene) polymer and asphalt blend that provides an extremely durable sheet with excellent weathering characteristics, flexibility and dimensional stability for ease of handling and quick installations.

Product Details

APPeX 4.5M

Product Short Description
APPeX® 4.5M is a cap or flashing sheet with ceramic-coated roofing granules that are specifically engineered for optimal embedment in the APP-blended sheet. The membrane is made up of an APP (Atactic Polypropylene) polymer and asphalt blend that provides an extremely durable sheet with excellent weathering characteristics, flexibility and dimensional stability for ease of handling and quick installations.

Features

APPeX 4.5M

Features

Meets the requirements of ASTM D 6222, Type I, Grade G

Ceramic-Coated Roofing Granules: Specifically engineered for optimal embedment in the APP-blended sheet. The ceramic coating promotes excellent long-term adhesion.

APP (Atactic Polypropylene) Polymer and Asphalt Blend: Provides an extremely durable sheet with excellent weathering characteristics, flexibility and dimensional stability for ease of handling and quick installations.

Polyester Reinforcement Mat: Provides bidirectional glass-scrim reinforcement and offers robust tear strength and puncture resistance, allowing for high wind performance and excellent hail rating. The sheet also exhibits strong dimensional stability and enhanced elongation.

Polyolefin Burn-Off Film: Promotes ease of heat welding.

Colors: White, Black, Tan, Brown, Grey, Terra Cotta, Weathered Wood, Chestnut, Burnt Sienna, Red, and Slate.

Documents

APP Installation and Details

When it comes to design, we've got the tools to get you from the desk to the roof. Here you will find all of the APP specifications, 3-part specs, details and installation guides. If you have any questions when it comes to installation, please contact our Specifier Services Group for design and your local technical representative for the field.

 
EDGECADPDF
BIT-4 (GTR) Roof Edge Gutter 
DWGPDF
BIT-4 Roof Edge with Presto Tite
DWGPDF

 
EXPANSION, TIE-IN AND TRANSITION*     CADPDF
BIT-1 (NLB) Base Flashing for Non Load Brng Wall-Curb to Wall EJDWGPDF
BIT- 5 Base Flashing for Non Load Bearing Wall & Metal EJ
DWGPDF
BIT- 7 Curb Mounted Roof to Roof EJ Cover
DWGPDF

*ALSO REFER TO SPECIALTY ROOFING PRODUCTS TRANSITION & INTERSECTION DETAILS

 
CURBS AND CORNERSCADPDF
BIT-8 Prefabricated CurbDWGPDF
BIT-26 Base Flashing at Outside Corner DWGPDF
BIT-27 Base Flashing at Inside corner DWGPDF

 
DRAINS, PIPES, AND VENTSCADPDF
BIT-9 Plumbing Vent DWGPDF
BIT-10 One Way Roof Vent - FP-10DWGPDF
BIT-11 Metal Drain DWGPDF
BIT-21 Primary Metal Scupper in SumpDWGPDF
BIT-22 Overflow Metal ScupperDWGPDF
BIT-23 Vent Stack (Warm)DWGPDF

 
PENETRATION, EQUIPMENT SUPPORT AND PROTECTIONCADPDF
BIT-16 Roof Penetration PanDWGPDF
BIT-17 Lighting Rod on Roof Surface DWGPDF
BIT-PT-01 Bituminous Light SupportDWGPDF
BIT-PT-02 Bituminous Medium SupportDWGPDF
BIT-PT-03 Bituminous Heavy SupportDWGPDF
BIT-PT-04 DynaTred Traffic Pads with Pavers
DWGPDF
BIT-PT-05 DynaTred Traffic Pads
DWGPDF

 
WALL FLASHINGCADPDF
BIT- 1 (LB) Base Flashing for Load Brng Wall with Counterflashing DWGPDF
BIT-2 (WL) Base Flashing for Wall less than 24 inches DWGPDF
BIT-3 (WH) Base Flashing for Wall more than 24 inched with Coping DWGPDF
BIT-3 (WL) Base Flashing for Wall less than 24 inches with Coping DWGPDF
BIT-6 (TH) Base Flashing for Wall more than 24 inches with Coping DWGPDF
BIT-6 (TL) Base Flashing for Wall less than 24 inches with Coping DWGPDF
BIT-15 (E) EPDM Wall Covering with BUR Base Flashing DWGPDF
BIT-15 (E) Alt-EPDM Wall Covering with BUR Base Flashing DWGPDF
BIT-15 (P) PVC Wall Covering with BUR Base Flashing DWGPDF
BIT-15 (T) TPO Wall Covering with BUR Base Flashing DWGPDF

Roof Area - Base Tie-In Attachment

 
CORNER DETAILSCADPDF
PMF-3 PermaFlash® Inside CornerDWGPDF
PMF-3S PermaFlash® Inside Corner ScrimDWGPDF

 
LAP ANGLE CHANGE DETAILSCADPDF
PMF-10 PermaFlash® Standard Base FlashingDWGPDF
PMF-9 PermaFlash® Standard Canted Base FlashingDWGPDF

Penetration, Equipment Support and Protection

 
CURB DETAILSCADPDF
PMF-4 PermaFlash® Curb CornerDWGPDF
PMF-4Sa PermaFlash® Outside Corner Scrim Detail (Top)DWGPDF
PMF-4Sb PermaFlash® Outside Corner Scrim Detail (Bottom)DWGPDF

 
DRAIN, PIPE AND VENT DETAILSCADPDF
PMF-5 PermaFlash®-To-DrainDWGPDF
PMF-5 (ALT) PermaFlash®-To-DrainDWGPDF
PMF-5S PermaFlash® Drain ScrimDWGPDF
PMF-7 PermaFlash® Through-Wall ScupperDWGPDF
PMF-7S PermaFlash® Through-Wall Scupper ScrimDWGPDF
PMF-8 PermaFlash® Overflow Scupper DetailDWGPDF
PMF-8S PermaFlash® Overflow Scupper Scrim Detail DWGPDF

 
EQUIPMENT SUPPORT DETAILSCADPDF
PMF-1 PermaFlash® I-BeamDWGPDF
PMF-11 PermaFlash® Square Metal TubeDWGPDF
PMF-11S PermaFlash® Square Metal Tube ScrimDWGPDF
PMF-1S PermaFlash® I-Beam ScrimDWGPDF
PMF-2 PermaFlash® Angle IronDWGPDF
PMF-2S PermaFlash® Angle Iron ScrimDWGPDF

 
PIPE PENETRATION DETAILSCADPDF
PMF-6 PermaFlash® Pipe PenetrationDWGPDF
PMF-6 (ALT) PermaFlash® Pipe PenetrationDWGPDF
PMF-6S PermaFlash® Pipe Penetration ScrimDWGPDF

 
EDGECADPDF
HW-4 (GS) Gravel StopDWGPDF
HW-4 (GS-ALT) Gravel Stop AlternateDWGPDF
HW-4 (GTR) GutterDWGPDF
HW-4 (PRESTO LOCK) Presto Lock Fascia SystemDWGPDF
HW-4 (PRESTO-TITE) Presto-Tite Edge Metal System                                                      DWGPDF
HW-4 (RMCF) Raised Metal Cant FasciaDWGPDF
HW-4 (GTR-ALT) Roof Edge Gutter ALTDWGPDF
HW-4 (RFS) Rail Fascia System Roof Edge DWGPDF

 
HEAT WELDABLE EXPANSION JOINT DETAILS*CADPDF
HW-1 (NLB) Base Flashing Curb to Wall EJDWGPDF
HW-5 (NLB-ALT) Base Flashing Metal EJ ALTDWGPDF
HW-7 Curb Mounted Roof-to-Roof Expansion Joint CoverDWGPDF

*ALSO REFER TO SPECIALTY ROOFING PRODUCTS TRANSITION & INTERSECTION DETAILS

 
CURBS AND CORNERSCADPDF
HW-8 Prefabricated CurbDWGPDF
HW-19 Roof Hatch CurbDWGPDF
HW-26 Base Flashing at Outside Corner                                                                      DWGPDF
HW-27 Base Flashing at Inside CornerDWGPDF

 
DRAINS, PIPES AND VENTSCADPDF
HW-9 Plumbing Vent
DWGPDF
HW-10 FP-10 One Way® Roof Vent     DWGPDF
HW-11 Metal DrainDWGPDF
HW-21 Primary Metal Scupper in Sump                                                                       DWGPDF
HW-22 Overflow Metal ScupperDWGPDF
HW-23 Vent Stack (Warm)
DWGPDF

 
PENETRATION, EQUIPMENT SUPPORT AND PROTECTIONCADPDF
HW-17 Lightning Rod on Roof Surface                                                                            DWGPDF
HW-16 Penetration PocketDWGPDF
HW-18 JM Energy AnchorDWGPDF

 
WALL FLASHINGCADPDF
HW-1 (LB) Masonry Wall w/ CounterflashingDWGPDF
HW- 2 (PT) Perma Tite Coping DWGPDF
HW-3 (WH) Wood Wall >24” with CopingDWGPDF
HW-3 (WL) Wood Wall <24” with CopingDWGPDF
HW-6 (TH) Masonry Wall >24” with CopingDWGPDF
HW-6 (TL) Masonry Wall <24” with CopingDWGPDF
HW- 6 (TL) ALT - Base Flashing For Masonry Wall DWGPDF
HW-15 (E) EPDM Wall Covering with Bituminous Base FlashingDWGPDF
HW-15 (P) PVC Wall Covering With Bit Base Flashing DWGPDF
HW-15 (T) TPO Wall Covering with Bituminous Base FlashingDWGPDF
HW-15 (T-ALT) TPO Wall Covering with Bituminous Base FlashingDWGPDF
HW-20 (WH) Gypsum Wall on Metal Studs >24” w/ CopingDWGPDF
HW-20 (WL) Gypsum Wall on Metal Studs <24” w/ CopingDWGPDF
HW-24 Venting Lightweight ConcreteDWGPDF
HW-25 (LB) Optional Two-Ply Base Flashing for Load-Bearing Masonry Wall w/ CounterflashingDWGPDF

VAPOR BARRIER SA DETAILSCADPDFBIM
VB-1 JM Vapor Barrier SA - Wall Base DetailDWGPDF-
VB-1 (ALT) JM Vapor Barrier SA - Wall Base Detail - Alt                                                DWGPDF-
VB-2 JM Vapor Barrier SA - Pipe Penetration DetailDWGPDF-
VB-3 JM Vapor Barrier SA - Drain DetailDWGPDF-
VB-4 JM Vapor Barrier SA - Detail at Field LapsDWGPDF-
VB-5 JM Vapor Barrier SA - Outside Curb DetailDWGPDF-
VB-6 JM Vapor Barrier SA - Inside Curb DetailDWGPDF-

VAPOR BARRIER SAR DETAILS                                                                                            CADPDFBIM
VB-1 JM Vapor Barrier SAR - Wall BaseDWGPDF-
VB-1 (ALT) JM Vapor Barrier SAR - Wall BaseDWGPDF-
VB-2 JM Vapor Barrier SAR - Pipe PenetrationDWGPDF-
VB-3 JM Vapor Barrier SAR - DrainDWGPDF-
VB-4 JM Vapor Barrier SAR - Field LapsDWGPDF-
VB-5 JM Vapor Barrier SAR - Outside CurbDWGPDF-
VB-6 JM Vapor Barrier SAR - Inside CurbDWGPDF-

Resources

APPeX 4.5M

Johns Manville APPeX sheets are easy to work with, you wont run into hooking which means straighter lines. Choose from a selection of color options so that you can have a long lasting beautiful roof. APPex is a durable option for any commercial roofing project.

Building Owner Resources

Johns Manville offers one of the most comprehensive portfolios of commercial low-slope roofing solutions. We have a long standing dedication to providing solution-based systems for building owners.

Codes Corner

Here you will find quick links and cheat sheets to Johns Manville roofing systems code approvals and ratings. 

Guarantees and Roof Maintenance

Support services can include: conceptual product information, building science, wind uplift data, national and local code understanding, FM Global® and UL® regulations, fastening patterns and sheet layouts, installation guidelines and standard details.

Recycling Resources

Re-roofing mechanically attached or ballasted insulated single-ply systems now have the potential for recycling versus contributing to a landfill.

SmartBinder Resource Library 

Your resource for all JM documents in one place. 

Submittal Wizard

The Submittal Wizard is a tool to help you pull together the necessary documents for your submittal package.

Explore More

Commercial Roofing News

Blog

Commercial Roofing Blog

Watch On-Demand

Video Library

Roofing Video Library

Expand Your Knowledge

Training

Training Page