JM EPDM R Systems

JM EPDM R Systems

Product Descriptive Name
Polyester-Reinforced Ethylene Propylene Diene Monomer Membrane
Product Short Description
Cured ethylene propylene diene monomer reinforced with a tough 1,000+ denier polyester mat.

Product Details

JM EPDM R Systems

Product Long Description

Features

JM EPDM R Systems

Features

Meets the requirements of ASTM D 4637, Type II

Membrane: Cured EPDM (ethylene propylene diene monomer) reinforced with a tough 1,000+ denier polyester mat.

Fully Extruded: Produces fewer air voids, more uniform thickness and smoother sheets.

Vulcanization Process: Produces a redundant waterproofing monolithic membrane.

Polymer Formulation: Performs in extreme temperature climates and withstands differential movement.

UV-Stabilization Properties: Offers superior ozone and weather resistance delivering one of the longest service lives available.

Technical Expertise: Backed by 30+ years of EPDM experience and installations

Color: Black

Documents

EPDM Installation and Details

When it comes to design, we've got the tools to get you from the desk to the roof. Here you will find all of the EPDM specifications, 3-part specs, details and installation guides. If you have any questions when it comes to installation, please contact our Specifier Services Group for design and your local technical representative for the field.

TPO System Detail Decoder

EPDM MASTER DETAILSCADPDFYear Term
E-FW-M1 EPDM Base & Wall Flashing with Coping Master DetailDWGPDF - 
E-FW-M1I EPDM Base & Wall Flashing with Coping Isometric View Master DetailDWGPDF - 
E-FW-M2I EPDM Self-Adhered Base and Wall Flashing with CopingDWGPDF-
E-FW-M3I EPDM Self-Adhered Continuous Wall FlashingDWGPDF20 Year

BASE TIE-IN DETAILSCADPDFYear Term
E-FW-B3 Base Tie-In - Fastener & PlateDWGPDF20 Year
E-FW-B4 Base Tie-In - Fastener & Plate On WallDWGPDF20 Year
E-FW-B5 Membrane Flashing Base Tie-In (High Internal Pressure)DWGPDF20 Year
E-FW-B7 EPDM Self-Adhered Base with Vertical Reinforced Termination Strip - RTSDWGPDF20 Year
E-FW-B8 EPDM Self-Adhered Base with Horizontal Reinforced Termination Strip - RTSDWGPDF20 Year
E-FW-B9 EPDM Self-Adhered Base Flashing with Sealing StripDWGPDF20 Year
3E-FW-B1 Base Flashing with Horizontal Termination Strip (RTS)     DWGPDF30 Year
3E-FW-B2 Base Flashing with Vertical Termination Strip (RTS)DWGPDF30 Year
3E-FW-B3 Base Flashing with Horizontal Polymer Batten StripDWGPDF30 Year
3E-FW-B4 Base Flashing with Vertical Polymer Batten StripDWGPDF30 Year
3E-FW-B5 Deck Obstruction Base Flashing with (RTS)DWGPDF30 Year
3E-FW-B6 Base Tie In (F&P) with 6 inch Sealing StripDWGPDF30 Year
3E-FW-B7 Base Tie In (Batten Strip) with 6 inch Sealing StripDWGPDF30 Year
3E-FW-B8 Base Tie In (Polymer Batten Strip) on Wall 6 inch Sealing StripDWGPDF30 Year
3E-FW-B9 Deck Obstruction Base Flashing with 6 inch Sealing StripDWGPDF30 Year

INTERMEDIATE TERMINATION DETAILSCADPDFTERM
E-FW-I3 EPDM Intermediate Termination with Termination BarDWGPDF20 Year
E-FW-I4 EPDM Intermediate Termination with Through-Wall Counter FlashingDWGPDF30 Year
E-FW-I5 EPDM Intermediate Termination Below Wall CladdingDWGPDF30 Year
3E-FW-I1 Intermediate Termination with CF and Cut in RegletDWGPDF30 Year
3E-FW-I2 Intermediate Termination with Surface MTD CFDWGPDF30 Year
3E-FW-I3 Intermediate Termination Below Wall CladdingDWGPDF30 Year
3E-FW-I4 Intermediate Flashing Attachment with Polymer Batten StripDWGPDF30 Year
3E-FW-I5 Intermediate Flashing Cover with Polymer Batten StripDWGPDF30 Year

TOP OF WALL DETAIL  CADPDFYear Term
E-FW-T1 Fabricated Metal Coping Over Adhered EPDMDWGPDF30 Year
E-FW-T4 Perma-Tite Continuous Cleat Coping System Over EPDMDWGPDF30 Year
3E-FW-T1 Top of Wall Termination with Stone CopingDWGPDF30 Year
3E-FW-T2 Presto-Lock Coping Over EPDMDWGPDF30 Year
3E-FW-T3 Fabricated Metal Coping Over Adhered EPDMDWGPDF30 Year
3E-FW-T4 Presto-Tite Fascia on Sloped ParapetDWGPDF30 Year
3E-FW-T5 Presto-Tite Fascia on Flat ParapetDWGPDF30 Year

EPDM MEMBRANE SEAMING DETAILSCADPDFYear Term
E-MS-01 Reinforced EPDM Membrane Cut Edge Lap CaulkDWGPDF - 
E-MS-02 EPDM Membrane Side Lap & T-JointDWGPDF20 Year
E-MS-03 EPDM Side Lap & T-Joint - 30 YearDWGPDF30 Year
E-MS-04 EPDM Side Lap & T-Joint - 30 YearDWGPDF30 Year
E-MS-05 In-Lap Fastening Method - Mechanically AttachedDWGPDF20 Year
E-MS-06 In-Lap Fastening Method - Steel DeckDWGPDF20 Year
E-MS-07 In-Lap Fastening Method - Plywood DeckDWGPDF20 Year
E-MS-08 In-Lap Fastening Method - Concrete DeckDWGPDF20 Year
E-MS-09 In-Lap Fastening Method - Wood Plank DeckDWGPDF20 Year
E-MS-10 Reinforced Perimeter Strip Fastening MethodDWGPDF20 Year
E-MS-11 Continuous Strip Fastening MethodDWGPDF20 Year
E-MS-12 Polymer Batten Strip Fastening MethodDWGPDF20 Year
E-MS-13 Slope Transition-ValleyDWGPDF20 Year
E-MS-14 Slope Transition-RidgeDWGPDF20 Year
E-MS-15 EPDM Self-Adhered Slope Transition (Valley)DWGPDF20 Year
E-MS-16 EPDM Self-Adhered Membrane Butted End LapDWGPDF20 Year
E-MS-17 EPDM Self-Adhered Side Lap and T- JointDWGPDF20 Year
E-MS-18 EPDM Self-Adhered Side Lap - Sealing Strip and T-JointDWGPDF20 Year
E-MS-PT1 Tape/Standard Sheet Assembly - Pre-TapedDWGPDF20 Year
E-MS-PT2 Tape/Standard Sheet Side Lap & T-Joint - Pre-TapedDWGPDF20 Year
E-MS-PT3 Tape/Standard Sheet Side Lap & T-Joint - 30 Year - Pre-TapedDWGPDF30 Year
E-MS-PT4 Tape/Standard Sheet Side Lap & T-Joint - 30 Year - Pre-TapedDWGPDF30 Year
E-MS-PT5 Tape/Tape Assembly - Pre-TapedDWGPDF - 
E-MS-PT6 Tape/Tape Side Lap & T-Joint - Pre-TapedDWGPDF20 Year
E-MS-PT7 Tape/Tape Side Lape & T-Joint - 30 Year - Pre-TapedDWGPDF30 Year
E-MS-PT8 Tape/Tape Side Lap & T-Joint - 30 Year - Pre-TapedDWGPDF30 Year
E-MS-PT9 Tape/Tape Side Lap With Polymer Batten BarDWGPDF20 Year
3E-MS-01 Lap Splice 6 inch Sealing StripDWGPDF30 Year
3E-MS-02 Lap Splice 6 inch Seam TapeDWGPDF30 Year
3E-MS-03 Lap Splice Under Wall Flashing with Sealing StripDWGPDF30 Year
3E-MS-04 Lap Splice Over Field Seam with Sealing StripDWGPDF30 Year
3E-MS-05 Lap Splice with 6 inch Sealing Strip EndlapDWGPDF30 Year
3E-MS-06 Lap Splice at Wall Flashing with Sealing StripDWGPDF30 Year

EPDM FLASHING CURB & CORNER DETAILSCADPDFYear Term
E-FC-01 Prefabricated Metal Curb Base FlashingDWGPDF20 Year
E-FC-02 Roof HatchDWGPDF20 Year
E-FC-03 EPDM Inside Corner with RTS StripsDWGPDF20 Year
E-FC-04 EPDM Inside Corner with RTS Strips - 30 YearDWGPDF30 Year
E-FC-05 EPDM Inside Corner with Seam TapeDWGPDF20 Year
E-FC-06 EPDM Inside Corner with Seam Tape - 30 YearDWGPDF30 Year
E-FC-07 EPDM Outside Corner with RTS StripsDWGPDF20 Year
E-FC-08 EPDM Outside Corner with RTS Strips - 30 YearDWGPDF30 Year
E-FC-09 EPDM Outside Corner with Seam TapeDWGPDF20 Year
E-FC-10 EPDM Outside Corner with Seam Tape - 30 YearDWGPDF30 Year
E-FC-11 Prefabricated water tight metal Curb Base Flashing           DWGPDF20 Year
E-FC-12 Wood Curb Base FlashingDWGPDF30 Year
E-FC-13 EPDM Inside Corner with Seam Tape and Vertical Wall FasteningDWGPDF20 Year
E-FC-14 EPDM Flashing Wall with Term Bar and Corner CopingDWGPDF - 
3E-FC-01 Prefab Water Tight Metal Curb Flashing 2 inch Max FlangeDWGPDF30 Year
3E-FC-02 Prefab Water Tight Metal Curb Flashing 2-3 inch FlangeDWGPDF30 Year
3E-FC-03 Outside Corner RTS Strip LayoutDWGPDF30 Year
3E-FC-04 Inside Corner RTS Strip LayoutDWGPDF30 Year
3E-FC-05 RTU Curb Flashing Sealing StripDWGPDF30 Year
3E-FC-06 RTU Curb Flashing with Metal CF Sealing StripDWGPDF30 Year
3E-FC-07 RTU Curb Flashing with RTSDWGPDF30 Year
3E-FC-08 Prefabricated Metal Curb Flashing with RTSDWGPDF30 Year
3E-FC-09 RTU Curb Base Flashing with Sealing StripDWGPDF30 Year
3E-FC-10 RTU Curb and Counter Flashing With Sealing StripDWGPDF30 Year
3E-FC-11 Outside Corner with JM Peel & Stick FlashingDWGPDF30 Year
3E-FC-11I Outside Corner with JM Peel & Stick Flashing InstallationDWGPDF30 Year
3E-FC-12 Outside Corner At Welded Watertight CurbDWGPDF30 Year
3E-FC-12I Outside Corner At Welded Watertight Curb InstallationDWGPDF30 Year
3E-FC-13 Inside Corner with JM Peel & Stick FlashingDWGPDF30 Year
3E-FC-13I Inside Corner with JM Peel & Stick Flashing InstallationDWGPDF30 Year
3E-FC-14 Inside Corner with Separate Wall FlashingDWGPDF30 Year
3E-FC-14I Inside Corner with Separate Wall Flashing InstallationDWGPDF30 Year
3E-FC-15 Outside Corner with Seam TapeDWGPDF30 Year
3E-FC-15I Outside Corner with Seam Tape InstallationDWGPDF30 Year
3E-FC-16I Inside Corner with RTS Strips InstallationDWGPDF30 Year
3E-FC-17I Outside Corner with RTS Strips InstallationDWGPDF30 Year

EPDM PROTECTION DETAILSCADPDFYear Term
E-PT-01 Support-LightDWGPDF - 
E-PT-02 Support-MediumDWGPDF - 
E-PT-03 Support-HeavyDWGPDF - 
E-PT-04 Walkway-Concrete PaverDWGPDF - 
E-PT-05 EPDM Peel & Stick Walkpads Over EPDM MembraneDWGPDF - 
E-PT-06 Ballasted EPDMDWGPDF - 
E-PT-07 Lightning Rod-Wall MountDWGPDF - 
E-PT-08 Lightning Rod-Roof MountDWGPDF - 
E-PT-09 JM ENRGY Anchor - EPDMDWGPDF20 Year
E-PT-10 Hurricane Peel Stop Anchor BarDWGPDF20 Year

PRE-MANUFACTURED (METAL) DETAILSCADPDFYear Term
E-FE-P1 JM Presto Lock Fascia Over EPDMDWGPDF30 Year
E-FE-P3 Rail Fascia System For Single Ply RoofsDWGPDF30 Year
E-FE-P4 JM Metal Drip Edge with JM EPDM Sealing StripDWGPDF20 Year
E-FE-P5 JM Gravel Stop with JM EPDM Sealing StripDWGPDF20 Year
3E-FE-P1 Presto Tite Fascia for Single Ply SystemsDWGPDF30 Year
3E-FE-P2 Extended JM Presto Tite FasciaDWGPDF30 Year
3E-FE-V2 Roof Edge Gutter with FlangeDWGPDF30 Year
3E-FE-V4 Metal Drip Edge with EPDM Sealing StripDWGPDF30 Year
3E-FE-V6 Gutter & Metal Edge with EPDM Sealing StripDWGPDF30 Year

EPDM DRAINS & VENTS DETAILCAD PDF Year Term
E-DV-01 Vent PipeDWGPDF20 Year
E-DV-02 Vent PipeDWGPDF30 Year
E-DV-03 Through-Wall ScupperDWGPDF20 Year
E-DV-04 Through-Wall ScupperDWGPDF30 Year
E-DV-04I Through-Wall ScupperDWGPDF30 Year
E-DV-05 Primary Scupper with Tapered Drainage SumpDWGPDF20 Year
E-DV-06 Low Wall Primary Scupper FlashingDWGPDF20 Year
E-DV-07 Overflow ScupperDWGPDF20 Year
E-DV-08 Primary Drain Sump - Low Slope - Less than 3:12 SlopeDWGPDF30 Year
E-DV-09 Primary Drain Sump - Steep Slope - Greater than 3:12 Slope Mech. Att. DWGPDF20 Year
E-DV-10 Primary Drain Sump - Steep Slope - Greater than 3:12 Slope AdheredDWGPDF20 Year
E-DV-11 Primary and Overflow Drain SumpDWGPDF30 Year
E-DV-12 JM EPDM Hercules RetrodrainDWGPDF20 Year
3E-DV-01 Roof DrainDWGPDF30 Year
3E-DV-02 Overflow Roof Drain with Water DamDWGPDF30 Year
3E-DV-03 Primary Roof Drain InsertDWGPDF30 Year
3E-DV-04 Primary and Overflow Roof DrainDWGPDF30 Year
3E-DV-05 Through Wall Welded Scupper SleeveDWGPDF30 Year
3E-DV-05I Through Wall Welded Scupper SleeveDWGPDF30 Year
3E-DV-06 Wall Overflow Welded Scupper SleeveDWGPDF30 Year
3E-DV-06I Wall Overflow Welded Scupper SleeveDWGPDF30 Year

EPDM FLASHING PENETRATION DETAILSCAD PDF Year Term
E-FP-01 JM Peel and Stick Pipe BootDWGPDF20 Year
E-FP-02 Field Fabricated Vent PipeDWGPDF20 Year
E-FP-04 Metal Penetration Pocket Over EPDMDWGPDF20 Year
E-FP-05 Vent Pipe - HotDWGPDF20 Year
E-FP-06 EPDM Pourable Sealer PocketDWGPDF20 Year
3E-FP-01 Penetration with JM Peel and Stick Pipe BootDWGPDF30 Year
3E-FP-02 Vent Pipe Penetration with Field Fabricated FlashingDWGPDF30 Year
3E-FP-03 Hot Stack Penetration with Field Fabricated FlashingDWGPDF30 Year
3E-FP-04 Metal Penetration Pocket with Peel and Stick FlashingDWGPDF30 Year
3E-FP-05 Penetration Pocket with Peel and Stick FlashingDWGPDF30 Year
3E-FP-06 Penetration Cover Strip Options for Pre-Molded FlashingDWGPDF30 Year

EPDM TIE-IN FLASHING DETAILSCAD PDF Year Term
E-TI-01 EPDM Transition to Sloped Shingle Roof                         DWGPDF20 Year
E-TI-02 Curb Tie-In to RoofDWGPDF20 Year
E-TI-03 Tie-In - Bituminous to EPDMDWGPDF20 Year
E-TI-04 Curb Tie-In to Roof with 6 inch Sealing Strip   DWGPDF30 Year
E-TI-05 Curb Tie-In to Roof with 6 inch Seam TapeDWGPDF30 Year
E-TI-06 EPDM Self-Adhered Transition to Sloped Shingle RoofDWGPDF20 Year

EPDM EXPANSION JOINT DETAILSCADPDFYear Term
E-EJ-01 Expansion Joint - Roof To WallDWGPDF20 Year
E-EJ-02 Expansion Joint - Roof To RoofDWGPDF20 Year
E-EJ-03 Expand-O-Flash Curb To Wall Expansion Joint Cover- Style CF/EJDWGPDF20 Year
E-EJ-04 Expand-O-Flash Roof To Roof Expansion Joint Cover - Style EJDWGPDF20 Year
E-EJ-05 Expand-O-Flash Roof To Wall - Style EJDWGPDF20 Year
E-EJ-06 Expand-O-Flash Curb To Curb Expansion Joint Cover - Style CFDWGPDF20 Year
E-EJ-07 Expand-O-Flash Curb To Wall Expansion Joint Cover - Style CF/EJDWGPDF20 Year
E-EJ-08 Expand-O-Flash Curb To Curb Expansion Joint Cover - Style EJ/WCDWGPDF20 Year
E-EJ-09 Expand-O-Flash Curb To Wall - Style EJ/WCDWGPDF20 Year
E-EJ-10 EJ Roof to Roof with 6 inch Seam TapeDWGPDF30 Year
E-EJ-11 EJ Roof to Roof with 6 inch Sealing StripDWGPDF30 Year
E-EJ-12 EJ Roof to Wall with 6 inch Sealing StripDWGPDF30 Year
E-EJ-13 EJ Roof to Wall with 6 inch Seam TapeDWGPDF30 Year
E-EJ-14 Roof to Roof with Expansion Slip PlateDWGPDF20 Year
3E-EJ-01 EJ Roof to Wall with RTS StripDWGPDF30 Year
3E-EJ-02 EJ Roof to Wall with 6 inch Sealing StripDWGPDF30 Year
3E-EJ-03 Roof to Roof Expansion Joint with RTS StripDWGPDF30 Year
3E-EJ-04 Roof to Roof Expansion Joint with 6 inch Sealing StripDWGPDF30 Year
3E-EJ-05 Expand-O-Flash Curb to Wall EJ Cover (RTS)DWGPDF30 Year
3E-EJ-06 Expand-O-Flash Curb to Wall EJ 6 inch Sealing StripDWGPDF30 Year
3E-EJ-07 Curb to Curb Field Fabricated Joint Cover with RTS StripDWGPDF30 Year
3E-EJ-08 Curb to Curb Field Fabricated Joint Cover 6 inch Sealing StripDWGPDF30 Year
3E-EJ-09 Curb to Curb Expansion Joint Cover with RTS StripDWGPDF30 Year
3E-EJ-10 Curb to Curb Expansion Joint Cover 6 inch Sealing StripDWGPDF30 Year

 
EPDM FIT Self Adhered DetailsCADPDFYear Term
E-FW-B7 EPDM Self-Adhered Base with Vertical Reinforced Termination Strip - RTSDWGPDF20 Year
E-FW-B8 EPDM Self-Adhered Base with Horizontal Reinforced Termination Strip - RTSDWGPDF20 Year
E-FW-B9 EPDM Self-Adhered Base Flashing with Sealing StripDWGPDF20 Year
E-FW-M2I EPDM Self-Adhered Base and Wall Flashing with CopingDWGPDF-
E-FW-M3I EPDM Self-Adhered Continuous Wall FlashingDWGPDF20 Year
E-MS-15 EPDM Self-Adhered Slope Transition (Valley)DWGPDF20 Year
E-MS-16 EPDM Self-Adhered Membrane Butted End LapDWGPDF20 Year
E-MS-17 EPDM Self-Adhered Side Lap and T- JointDWGPDF20 Year
E-MS-18 EPDM Self-Adhered Side Lap - Sealing Strip and T-JointDWGPDF20 Year
E-TI-06 EPDM Self-Adhered Transition to Sloped Shingle RoofDWGPDF20 Year

VARIOUS (MISCELLANEOUS) DETAILSCAD PDF Year Term
E-FE-V1 Wood Nailer AttachementDWGPDF - 
E-FE-V2 Metal Drip Edge with EPDM Sealing StripDWGPDF20 Year
E-FE-V4 Gravel Stop with JM EPDM Sealing StripDWGPDF20 Year
E-FE-V6 Gutter & Metal Edge with EPDM Sealing StripDWGPDF20 Year
E-FE-V7 Gutter & JM Drain BarDWGPDF20 Year
E-FE-V8 Gutter & Term BarDWGPDF20 Year

 
SINGLE PLY LIQUID FLASHING CURB AND CORNER DETAILCADDWGBIM
SPL-FC-02 Typical EPDM Door Sill FlashingPDFDWG-

 
SINGLE PLY LIQUID FLASHING DRAINS AND VENTS DETAILSCADPDFBIM
SPL-DV-02 Throughwall Metal Scupper with EPDM MembraneDWGPDF-

 
SINGLE PLY LIQUID FLASHING PENETRATION DETAILSCADPDFBIM
SPL-FP-02 EPDM Roof Multi-Pipe Penetration FlashingDWGPDF-
SPL-FP-04 EPDM Square Tube Penetration FlashingDWGPDF-
SPL-FP-06 EPDM Wide Flange Penetration FlashingDWGPDF-
SPL-FP-07 Wide Flange Flashing Scrim LayoutDWGPDF-
SPL-FP-09 EPDM Angle Iron Penetration FlashingDWGPDF-
SPL-FP-10 Angle Iron Flashing Scrim LayoutDWGPDF-

SINGLE PLY LIQUID FLASHING WALL DETAILCADPDFBIM
SPL-FW-02 Wall Mounted Ladder EPDM Base FlashingDWGPDF-
SPL-FW-04 Deck Mounted Ladder EPDM Base FlashingDWGPDF-
SPL-FW-05 Flashing Wall Optional TerminationsDWGPDF-

SINGLE PLY LIQUID FLASHING EXPANSION JOINTS DETAILS CADPDFBIM
SPL-EJ-02 Expansion Joint EPDM Roof to WallDWGPDF-

SINGLE PLY ONE-PART POURABLE SEALER DETAILSCADPDFBIM
T1P-FP-04 Wide Flange Flashing Scrim Layout 1-Part Pourable Sealer Liquid FlashingDWGPDF-
T1P-FP-06 Angle Iron Flashing Scrim Layout 1-Part Pourable Sealer Liquid FlashingDWGPDF-

VAPOR BARRIER SA DETAILSCADPDFBIM
VB-1 JM Vapor Barrier SA - Wall Base DetailDWGPDF-
VB-1 (ALT) JM Vapor Barrier SA - Wall Base Detail - Alt                                                DWGPDF-
VB-2 JM Vapor Barrier SA - Pipe Penetration DetailDWGPDF-
VB-3 JM Vapor Barrier SA - Drain DetailDWGPDF-
VB-4 JM Vapor Barrier SA - Detail at Field LapsDWGPDF-
VB-5 JM Vapor Barrier SA - Outside Curb DetailDWGPDF-
VB-6 JM Vapor Barrier SA - Inside Curb DetailDWGPDF-

VAPOR BARRIER SAR DETAILS                                                                                            CADPDFBIM
VB-1 JM Vapor Barrier SAR - Wall BaseDWGPDF-
VB-1 (ALT) JM Vapor Barrier SAR - Wall BaseDWGPDF-
VB-2 JM Vapor Barrier SAR - Pipe PenetrationDWGPDF-
VB-3 JM Vapor Barrier SAR - DrainDWGPDF-
VB-4 JM Vapor Barrier SAR - Field LapsDWGPDF-
VB-5 JM Vapor Barrier SAR - Outside CurbDWGPDF-
VB-6 JM Vapor Barrier SAR - Inside CurbDWGPDF-

Resources

JM EPDM - Thicker. Smoother. Cleaner. Better.

Our commitment to EPDM, and you, remains as strong as ever.

Building Owner Resources

Johns Manville offers one of the most comprehensive portfolios of commercial low-slope roofing solutions. We have a long standing dedication to providing solution-based systems for building owners.

Codes Corner

Here you will find quick links and cheat sheets to Johns Manville roofing systems code approvals and ratings. 

Guarantees and Roof Maintenance

Support services can include: conceptual product information, building science, wind uplift data, national and local code understanding, FM Global® and UL® regulations, fastening patterns and sheet layouts, installation guidelines and standard details.

Recycling Resources

Re-roofing mechanically attached or ballasted insulated single-ply systems now have the potential for recycling versus contributing to a landfill.

SmartBinder Resource Library 

Your resource for all JM documents in one place. 

Submittal Wizard

The Submittal Wizard is a tool to help you pull together the necessary documents for your submittal package.

Explore More

Commercial Roofing News

Blog

Commercial Roofing Blog

Watch On-Demand

Video Library

Roofing Video Library

Expand Your Knowledge

Training

Training Page